iSMART BMS is a compact and cost-effective BMS for automotive and industrial Application ranging from 9VDC up to 135VDC. It manages rechargeable lithium batteries of any chemistry and from any battery supplier allowing you maximum battery sourcing freedom.
iSMART BMS manages 3–32 cells & max of 3 On-Board temperature sensors per board.
Sino | Parameter | iSMART BMS -15S | iSMART BMS -10S | iSMART BMS -5S | iSMART BMS -15S |
---|---|---|---|---|---|
1 | System Voltage | 18 – 75VDC | 15 – 50VDC | 9 – 25VDC | 24 – 135VDC |
2 | Cells | 9-15 Cells | 6-10 Cells | 3-5 Cells | 6-32 Cells |
3 | Capacity | 250Ah Max | 150Ah Max | 100Ah Max | 250Ah Max |
4 | Balancing Type | Passive | Passive | Passive | Passive |
5 | Balancing current | 20mA @ 4.2VDC Max (for more current option contact factory) | 20mA @ 4.2VDC Max (for more current option contact factory) | 20mA @ 4.2VDC Max (for more current option contact factory) | 1000mA @ 4.2VDC Max |
6 | Input voltage | Operates form Battery Power | Operates form Battery Power | Operates form Battery Power | 24 VDC (9VDC – 65VDC) |
7 | Current consumption | <65mA operating / <3mA sleep mode | <65mA operating / <3mA sleep mode | <65mA operating / <3mA sleep mode | <65mA operating / <3mA sleep mode |
8 | Temperature Sensors | 3 for Battery pack monitoring NTC, 10KΩ @ 25 DegC, β Value: 3900 | 2 for Battery pack monitoring NTC, 10KΩ @ 25 DegC, β Value: 3900 | 1 for Battery pack monitoring NTC, 10KΩ @ 25 DegC, β Value: 3900 | 16 for Battery pack monitoring NTC, 10KΩ @ 25 DegC, β Value: 3900 |
9 | Measurement Specifications | Cell voltage: Range 0-5V, Accuracy ±2mV typical, <±10mV max., Sampling 1Hz Temperature accuracy ±1.5°C (dependent on sensor) Pack voltage 0-80V, accuracy ±1V, Sampling 5Hz Current measurement by Shunt (100 – 1000 μΩ), 400mV max, Sampling 5Hz | Cell voltage: Range 0-5V, Accuracy ±2mV typical, <±10mV max., Sampling 1Hz Temperature accuracy ±1.5°C (dependent on sensor) Pack voltage 0-80V, accuracy ±1V, Sampling 5Hz Current measurement by Shunt (100 – 1000 μΩ), 400mV max, Sampling 5Hz | Cell voltage: Range 0-5V, Accuracy ±2mV typical, <±10mV max., Sampling 1Hz Temperature accuracy ±1.5°C (dependent on sensor) Pack voltage 0-80V, accuracy ±1V, Sampling 5Hz Current measurement by Shunt (100 – 1000 μΩ), 400mV max, Sampling 5Hz | Cell voltage: Range 0-5V, Accuracy ±2mV typical, <±10mV max., Sampling 1Hz Temperature accuracy ±1.5°C (dependent on sensor) Pack voltage 0-135V, accuracy ±1V, Sampling 5Hz Current measurement by Shunt (100 – 1000 μΩ), 400mV max, Sampling 5Hz |
10 | Dimensions | 235 x 70 x 24 mm (including heat sink mounted in PCB) | 210 x 70 x 24 mm (including heat sink mounted with PCB) | 180 x 70 x 24 mm (including heat sink mounted with PCB) | 220 X 182 mm (including heat sink mounted with PCB) |
11 | Coating | 3M™ Novec™ electronic coating EGC-1700 | 3M™ Novec™ electronic coating EGC-1700 | 3M™ Novec™ electronic coating EGC-1700 | 3M™ Novec™ electronic coating EGC-1700 |
12 | Communication | CAN bus 2.0 A&B for system integration, RS232 PC diagnostics interface | CAN bus 2.0 A&B for system integration, RS232 PC diagnostics interface | CAN bus 2.0 A&B for system integration, RS232 PC diagnostics interface | CAN bus 2.0 A&B for system integration, RS232 PC diagnostics interface |
13 | Protection Modes | Capable to monitor and handle 12 safety critical error modes Capable to report 12 unique warnings conditions Capability to broadcast system status, errors and warnings over CAN | Capable to monitor and handle 12 safety critical error modes Capable to report 12 unique warnings conditions Capability to broadcast system status, errors and warnings over CAN | Capable to monitor and handle 12 safety critical error modes Capable to report 12 unique warnings conditions Capability to broadcast system status, errors and warnings over CAN | Capable to monitor and handle 22 safety critical error modes Capable to report 15 unique warnings conditions Capability to broadcast system status, errors and warnings over CAN |
14 | Temperature | Specifications: Operational -40° to 105°C | Specifications: Operational -40° to 105°C | Specifications: Operational -40° to 105°C | Specifications: Operational -40° to 85°C |